Sale!

High Pressure Horizontal Chamber Autoclave Sterilizer with Auto Dry

৳ 620,000.00

CATEGORYHIGH PRESSURE AUTOCLAVE
CAPACITY 150 LTR
Max Sterilization Temperature(°C)132±2
maximum boiler pressure2.2 ±0.1kg / cm 2
sterilization pressure1. 4 kg/cm2
USAGEhospital, clinic, and laboratories
Operate Pressure(kg/cm2)2.0±0.1
SAFETY FEATURESafety Valve, PRESSURE LOCK
FUNCTION FORinstruments, cloth, glassware, and liquid
SPECIAL FEATUREvacuum drying feature

Product Description:

Horizontal high pressure cylindrical steam sterilizer with code sa-450 -143 liters with following features : Wide range of usage: “pointer” autoclaves provide sterilization pressure 1. 4 kg/cm2 approx. 122oc. which are suitable for wrapped / unwrapped materials, utensils, liquid(optional), and etc. widely used in hospital, clinic, and laboratories.low water indication: the “low water” indication lamp will light-on and stop all functions in the same time, when water in the steam generator, is not enough.stainless steel chamber supporter: the chamber is supported by heavy tubular stainless stand with stainless steel floor flanges for level adjustment.double wall chamber design: the autoclave designed with double wall, and the Chamber & jacket Are separated with steam generator. So, the dry function would be perfect.Pre-heating program: pre-heating by jacket (double Wall design), which can not only to keep the chamber temperature in balance, but also to offer the perfect dry function. And the best sterilization functions.

Practical Sterilization Function:
The preset vacuum feature will shorten the time of sterilization.
The vacuum drying feature will quickly remove undesirable moisture and meet the test requirements of Bowie Dick.
Tissue/appliance & glass/liquid, sterilization Dynamic switch mode can be selected to switch between different types of sterilizable materials. When liquid sterilization, make sure liquid ingredients to avoid rust and corrosion occurred. Please select stainless steel for medical & chemical products, physiological salt water, etc.
Auto Water Supply Device: The electrical control system can automatically detect and detect the volume of water. If the water volume is low, it will supply.

Safety Devices:
The system will cut off the heating power automatically to prevent overheating, dry-out or even meltdown of the heating device.
Pressure Controller with a maximum boiler pressure of 2.2 ±0.1kg / cm 2. When the pressure reaches the set value, to prevent the pressure from rising, the heating power will be automatically off.
Safety Valve, when the pressure reaches 2,5kg / cm 2, the quick exhaust of the vapor will start and release the chamber pressure.
Pressure Lock, if the internal chamber pressure exceeds 0.2kg / cm2, the clutch is automatically locked and the door cover can not be opened to keep the operator safe.
Safety Door Cover switch, wheel.